HKLII Hong Kong Regulations

[Index] [Search] [Notes] [Noteup] [Download (Current & Past)] [Download (Current only)] [繁體中文] [Help]

BUILDING (CONSTRUCTION) REGULATIONS

- CHAPTER 123B

TABLE OF PROVISIONS

           Long Title

   1.      Citation
   2.      Interpretation
   3.      Materials
   4.      Appropriate limitations not to be exceeded
   5.      Method of design
   6.      Overloading
   7.      Adjoining and other building or land not to be adversely affected
   8.      Changes in level
   9.      Site investigation
   9A.     Building design and construction in connection with lifts and
           escalators
   10.     Cement
   11.     Sand
   12.     Water
   13.     Materials for damp proofing
   14.     Chunam
   15.     Resistance to sliding, uplift and overturning
   16.     Dead loads
   17.     Imposed loads
   18.     Wind loads
   19.     Notice as to load
   20.     Site formation works
   21.     Bulk excavation in area number 1 of the scheduled areas
   22.     Interpretation
   23.     Foundation works
   24.     Site investigation
   25.     Allowable capacity for bearing, bond or friction of ground
   26.     Pile foundations
   27.     Cast-in-place concrete foundations
   28.     Horizontal restraints to piles and pile caps
   29.     On site tests to be made where doubt exists
   30.     Proof tests on foundation units
   31.     Ground treatment
   32.     Covering of sites
   33.     Areas to be paved
   34.     Certain floors to be impermeable
   35.     Floor next above external ground level
   36.     Skirting
   37.     Interpretation
   38.     External wall of buildings
   39.     Cladding
   40.     No timber in walls
   41.     Protection against penetration of moisture
   42.     Interpretation
   43.     Curtain walls
   44.     Application of regulations
   45.     Provision of flues
   46.     Construction of chimneys and fireplaces
   47.     Corrosion
   48.     Roofs to be weatherproof
   49.     Flat roof
   50.     Cement
   51.     Aggregate
   52.     Water
   53.     Admixtures
   54.     Reinforcement
   55.     Pre-stressing tendons
   56.     General
   57.     Designed mix concrete strengths
   58.     Concrete cubes
   59.     Acceptance criteria
   60.     Concrete for minor structural and non-structural works
   61.     Formwork
   62.     Minimum cover of reinforcement
   63.     Core testing
   64.     Interpretation
   65.     General requirement
   66.     Filters
   67.     Backfill material
   68.     Earth pressure
   69.     Water pressure
   70.     Minimum pressure
   71.     Retaining wall design
   72.     Loading condition
   73.     Site investigation
   74.     Adequate factor of safety
   75.     Validity of design earth pressure
   76.     Masonry and mass concrete walls
   77.     Drainage measures to preserve stability
   78.     Performance of drainage system
   79.     Surface channels
   80.     Safety required during excavation and construction
   81.     Weep holes
   82.     Copings
   83.     Bonding and foundation required
   84.     Bond courses required
   85.     Permission from Building Authority to sink or reopen wells
   86.     Performance
   87.     Wells prohibited in certain places
   88.     Wells to be covered and lined
   89.     Safety measures required
   90.     Fire resisting construction
   91.     Harbourage of vermin
   92.     (Omitted as spent)
   93.     Transitional

[ Note: This table has been automatically generated and may be incomplete. ]



[Index] [Search] [Notes] [Noteup] [Download (Current & Past)] [Download (Current only)] [繁體中文] [Help]