FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - CHAPTER 59O FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - LONG TITLE Empowering section VerDate:30/06/1997 (Cap 59, section 7) [1 September 1976] L.N. 205 of 1976 (L.N. 123 of 1976) FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 1 Citation VerDate:30/06/1997 These regulations may be cited as the Factories and Industrial Undertakings (Good Lifts) Regulations. FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 2 Application VerDate:30/06/1997 These regulations apply to any lift used in an industrial undertaking, which is- (a) a goods lift to which the Lifts and Escalators (Safety) Ordinance (Cap 327) applies by virtue of section 3 of that Ordinance but which has been exempted under section 44A from the application of that Ordinance; (b) a service lift to which the Lifts and Escalators (Safety) Ordinance (Cap 327) does not apply by virtue of section 3(1)(a)(xiv) of that Ordinance. FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 3 Interpretation VerDate:30/06/1997 In these regulations, unless the context otherwise requires- "competent examiner" (合資格檢驗員) in relation to the carrying out of any examination of a lift required by these regulations, means a person- (a) who is appointed for that purpose by the owner of the lift; and (b) whose name appears on the register of lift engineers kept by the Director of Electrical and Mechanical Services in pursuance of section 5 of the Lifts and Escalators (Safety) Ordinance (Cap 327); (13 of 1995 s. 2) "lift" (升降機) means a lifting machine or appliance having a car or platform the direction of movement of which is restricted by a guide or guides; "maintained" (維修、保持) means maintained in an efficient state, in efficient working order and good repair; "owner" (擁有人), in relation to a lift, includes the proprietor of an industrial undertaking in which the lift is used, the lessee or hirer of the lift, and any agent or person in charge or having the control or management of the lift. "competent examiner" (合資格檢驗員) "lift" (升降機) "maintained" (維修、保持) "owner" (擁有人) FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 4 Construction VerDate:30/06/1997 The owner of a lift shall ensure that it is not put into operation or used unless- (a) it is of good mechanical construction and made of strong and sound materials; and (b) it is properly maintained. FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 5 Examination VerDate:30/06/1997 (1) The owner of a lift shall cause it to be thoroughly examined by a competent examiner at least once annually and a report of the examination to be entered in the register kept under regulation 6. (L.N. 162 of 1976) (2) Where an examination under paragraph (1) shows that the lift cannot be used with safety unless certain repairs are carried out immediately, or within a specified time, the examiner shall, not later than 28 days after the completion of the examination, send a copy of the report of the examination to the Commissioner. FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 6 Register of examination to be kept by owner VerDate:09/06/2000 (1) The owner of a lift required to be examined under regulation 5 shall keep a register containing a report of every examination carried out on the lift. (2) The register shall be in the form prescribed in the Schedule and each entry therein shall be signed by the person carrying out the examination. (3) On being requested to do so by an occupational safety officer, the owner of a lift shall produce the register for inspection. (32 of 2000 s. 48) FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 7 Liftway to be enclosed VerDate:30/06/1997 (1) The liftway of a lift shall be efficiently protected by a substantial enclosure fitted with doors. (L.N. 587 of 1995) (2) Every such door shall be fitted with an efficient locking device of such a type that- (a) the door cannot be opened except when the car or platform is at rest at the landing place to which the door gives access; and (b) the car or platform cannot be moved away from the landing place until the door is fully closed and locked. (3) Nothing in paragraph (2) shall prevent any such door from being opened- (a) in an emergency; or (b) during any period when the lift is being used solely for the purpose of repairs or examination under regulation 5, whether or not the car or platform is at rest at the lift landing place to which the door gives access. (4) The enclosure of a liftway shall be so constructed as to prevent, when the doors are closed, any person entering or falling down the liftway or coming into contact with any moving part of the lift. (5) The lift and the enclosure of the liftway shall be so constructed as to prevent any part of any goods carried in the car or platform from being trapped between any part of the car or platform and any of the moving parts of the lift or any fixed structure. (6) The owner of a lift shall ensure that it is not used unless it complies with paragraphs (1), (2), (4) and (5). FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 8 Lighting, stopping, prevention of overrunning VerDate:30/06/1997 (1) There shall be provided and maintained for every lift- (a) adequate lighting for the car or platform; (b) at each landing place, a "stop" switch or "stop" push for stopping the lift; and (c) automatic devices to prevent the lift from overrunning. (2) No operating switch shall be installed in or on the car or platform of the lift. (3) The owner of a lift shall ensure that the lift is not used unless it complies with paragraphs (1) and (2). FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 9 Overloading and carriage of persons VerDate:30/06/1997 (1) There shall be conspicuously displayed in or on the car or platform of a lift easily legible notices in English and Chinese stating- (a) the maximum working load which the lift can safely carry; and (b) that the carriage of persons in the lift is prohibited. (2) No load greater than the load stated in the notice under paragraph (1)(a) shall be carried in a lift. (3) No person shall travel, or cause or permit any other person to travel, in a lift. (4) The owner of a lift shall ensure that the lift is not used- (a) unless notices are displayed in accordance with paragraph (1); or (b) in breach of paragraph (2) or (3). FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 10 Duty of person engaged in operating lift to report defect VerDate:30/06/1997 Every person engaged in the operation of a lift shall report forthwith to the owner thereof any defect in the operation mechanism or safety devices fitted to the lift or liftway. FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 11 Offences by owners and others VerDate:30/06/1997 (1) Any owner of a lift who contravenes any of the provisions of regulation 4 or 5(1) shall be guilty of an offence and shall be liable on conviction to a fine of $200000. (L.N. 325 of 1981) (2) Any owner of a lift who contravenes any of the provisions of regulation 6, 7(6), 8(3) or 9(4) shall be guilty of an offence and shall be liable on conviction to a fine of $50000. (L.N. 325 of 1981) (3) Any person who contravenes any of the provisions of regulation 9(2) or (3) or 10 shall be guilty of an offence and shall be liable on conviction to a fine of $10000. (4) Any person engaged in the operation of a lift who wilfully and without reasonable cause does anything likely to endanger himself or others shall be guilty of an offence and shall be liable on conviction to a fine of $50000. (5) Any person who knowingly misuses or interferes with any operation mechanism or safety device fitted to any part of a lift or liftway shall be guilty of an offence and shall be liable on conviction to a fine of $50000. (L.N. 325 of 1981; L.N. 33 of 1994) FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 12 Offences by competent examiners VerDate:30/06/1997 (1) Any competent examiner who, having carried out any examination for the purposes of these regulations- (a) fails to comply with regulation 5(2); or (b) fails or refuses to sign, within a reasonable time after the examination, a register under regulation 6(2), shall be guilty of an offence and shall be liable on conviction to a fine of $50000. (2) Any competent examiner who, having carried out any examination for the purposes of these regulations- (a) delivers to the owner or makes a report of the examination; or (b) signs an entry in the register kept under regulation 6(2), which is to his knowledge false as to a material particular shall be guilty of an offence and shall be liable on conviction to a fine of $200000 and to imprisonment for 12 months. (71 of 1989 s. 13) (L.N. 325 of 1981; L.N. 33 of 1994) FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - REGULATION 13 Saving VerDate:30/06/1997 The provisions of these regulations shall be in addition to and not in derogation of any of the provisions of the Buildings Ordinance (Cap 123). FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS - SCHEDULE SCHEDULE VerDate:30/06/1997 [regulation 6(2)] FACTORIES AND INDUSTRIAL UNDERTAKINGS (GOODS LIFTS) REGULATIONS REGISTER GOODS LIFTS REPORT OF ANNUAL THOROUGH EXAMINATIONS Form prescribed by the Commissioner for Labour for the purposes of regulation 6(2) of the Factories and Industrial Undertakings (Goods Lifts) Regulations Description of goods lift e.g. type, identification marks, maximum safe working load etc. (1) Date of Examination (2) Result of examination. Enter details of repairs required or defects. If none enter "in good order" (3) Signature of person making or responsible for examination (4) Date of entry in this Register (5) (L.N. 162 of 1976; L.N. 570 of 1995)