FACTORIES AND INDUSTRIAL UNDERTAKINGS (CARTRIDGE-OPERATED FIXING TOOLS) REGULATIONS - REGULATION 5
Operational condition of tools
(1) Every tool shall be maintained in such condition that it can be operated
only-
(a) when fitted with a splinter guard at right angles to the axis of the
barrel and at the end of the barrel. In the case of a direct-acting
tool the splinter guard shall be so maintained that the distance from
the outer edge of the guard to the axis of the barrel shall not be
less than 50 mm;
(b) when the splinter guard is in firm contact with the material to be
pierced and the splinter guard and barrel are fully pressed home
against the surface of the material;
(c) when the barrel and splinter guard are pressed against the surface of
the material to be pierced with a pressure exceeding 5 kg; and
(d) in the case of a direct-acting tool, when the axis of the barrel is at
an angle of less than 7 degrees to a line perpendicular to the work
surface.
(2) Every tool shall be maintained in such condition that it cannot operate-
(a) when the tool is being loaded;
(b) when the tool is dropped on to a hard surface from a height not
exceeding 300 cm; and
(c) when any part of the tool has been assembled incorrectly or when the
separate parts required to be dismantled or manipulated for loading
have not been firmly locked together.
(3) Every tool shall be maintained properly and free from patent defects.