Construction
(1) Every cesspool shall be-
(a) constructed of-
(i) brickwork in cement mortar;
(ii) concrete; or (L.N. 439 of 1990)
(iii) other approved material;
(b) so constructed and finished as to be impervious to liquid either from
the inside or the outside;
(c) covered with a reinforced concrete cover;
(d) provided with adequate access for cleaning purposes; and
(e) adequately ventilated.
(2) The internal faces of every cesspool shall be rendered with cement mortar.