BUILDING (CONSTRUCTION) REGULATIONS - REGULATION 38
External wall of buildings
Every external wall of a building shall be constructed of-
(a) masonry not less than 225 mm thick;
(b) plain concrete or reinforced concrete not less than 100 mm thick;
(c) any of the materials mentioned in paragraph (a) or (b) in combination
with a framework of steel or reinforced concrete; or
(d) other suitable materials of permanent, non-combustible and impervious
construction. (Enacted 1990)