BUILDING (CONSTRUCTION) REGULATIONS - REGULATION 14
Chunam
(1) Chunam shall-
(a) be composed of cement, hydrated lime, non-organic soil and water to
form a durable and impermeable material;
(b) be applied in 2 layers, each about 20 mm thick, with a well-keyed
surface to the bottom layer and with lapped daywork joints; and
(c) where the surface gradient exceeds 1 in 2, be adequately restrained
from slipping.
(2) A weep hole, with an internal diameter of not less than 50 mm, shall be
provided to every 1.5 m2 of the face of chunamed surface and in areas of
localized seepage. (Enacted 1990)